Mapping of several newly installed Air Liquide chemical pipeline to the BASF production plant in the Antwerp harbour.
Gas
Belgium
Cargill
Locating of a newly installed gas supply pipeline linking two production plants.
National Gas Transport
Belgium
Fluxys NV
Fluxus installation specifications obligate contractors of trenchless network installations to verify the XYZ locating using "Reduct Ductrunner gyro system or similar". Over the last 2 years, Reduct has provided services in 12 network installation projects with individual network sections up to 450m. Steel pipe diameters serviced ranged from 160 to 300mm.
National Electricity Grid
Belgium
Electrabel
Mapping of multiple river crossings of 200mm steel pipe segments up to 730m each.
Telecom
Belgium
Net Net Telecom
Mapping of 16km of 50mm PE duct network for fiber cables.
Gas/Oil
France
Sagem
Mapping of a new 950m HDD installation of a 600mm steel pipeline near Aix-en Provence.
Telecom
France
Level 3 Communications
Mapping of several HDD installations of 50mm telecom ducts.
National Gas Transport
Germany
ECB Geo GmbH
After several unsuccessful attempts to locate a gas main underneath a steel reinforced foundation along a canal near Berlin, Germany, the engineering firm coordinating the project called in the help of Reduct. Entering the main from a manhole 300m away on the other side of the canal, Reduct was able to establish the exact location to within 30cm. The nearest 'unsuccessful attempt' was more than 9m away.
National Gas Transport
Germany
RuhrGas GmbH
Mapping of multiple river crossings of 200mm steel pipe segments up to 1,060m each.
Telecom
Germany
Deutsche Telecom GmbH
Mapping of 10 x 160mm HDPE ducts with a length of 550m underneath the Elbe River in Hamburg, Germany.
National Gas Transport
Netherlands
GasUnie NV
Locating of multiple HDD steel pipe installations from200 to 300mm, including an offshore to onshore HDD drilling of 660m.
Waterways
Netherlands
Dutch Water Authorities
In 2004, a section of a dyke protecting the sub sea-level countryside in the south of Holland from flooding collapsed. The fact emerged that a water main running underneath the dyke had sprung a leak caused the soil to saturate initiating the collapse. Reduct NV was called in by the insurance companies as an independent expert to establish the exact position of the water main after the incident in order to help determine the cause of the leak.
Oil
United Kingdom
Conoco Ltd.
Reduct's Pipeline Mapping system was integrated into a Magnetic Flux Leakage pig during the inspection of 4,8km of crude pipeline to an off shore crude tanker mooring facility.
Municipality
United States of America
Penn Township, PA
Utilized robotic camera to pull DuctRunner through 8 diameter terracotta and PVC pipes and determined actual location of one pipe was 11 ft off of center of previously identified pipeline location.
Sewer
United States of America
Reynolds Inliner, Maitland FL
Mapping of 18 diameter CMP storm sewer relining project. Integrated our mapping and GIS service with relining technology.
Sewer
United States of America
Digital Engineering, Waveland MS
Mapping of 8 diameter PVC Gravity Sewer, 620 ft long spanning 3 manholes. Waveland trying to salvage existing lines and rebuild others after Katrina floods.
Water
United States of America
MidAtlantic Pipe, Washington DC
Mapping of newly installed 8 diameter cast iron pipe for client on short notice. Water main was in downtown Washington, DC